Hãng sản xuất: SEW - Đài Loan Model: LVD-415 Requires no batteries. |
|
Every circuit is doubled. | |
Buzzer indicates voltage detected. | |
Led indicates voltage detected. | |
Neon scale indicates voltage. | |
Dual HBC fuses. | |
High grade fiber glass probes. | |
Super polished fiber glass. | |
High strength connecting cord. | |
IEC/EN 61010-031 CAT IV 450V. | |
Heavy-duty rated. | |
Replaceable tips. | |
Choice of tips available. | |
Light weight. | |
Small storage space. | |
Strong strength reliefs. | |
Double poles non-polarized. | |
Suitable for 45 to 70Hz Networks. | |
Contact detector-type. Passive circuitry. | |
Fiber Glass 1.6mm - CU 35um PCB. | |
Super bright neon lights and LEDs. Ergonomically designed. |
Have you ever try to measure the voltage between overhead lines or between Line and Earth? If you did it using a normal meter and mormal test leads, this can be very dangerous. This is why the Double Check (LVD-415) was initially designed. Double Check is a visual voltmeter with a neon lights scale which lights proportionally to the voltage between the sticks. It features a bright LED and loud sound indication on each side. |
Both testers are identical. It is a CAT IV double pole measurement system which has it's poles long enough to be clear of the lines while testing them. These poles are made out of highly insulating super polished high grade fiber glass. Their color is highly visible and it's strong and durable. |
Both poles are electrically connected by a high strength spiraled and highly insulated cord which is securely held by customized strenght reliefs. Each circuit is fully fused by high breaking capacity fuses. |
Safety has been the most important factor while developing this product. Each circuit is present on the left pole as well as on the right pole. Each circuit works independently from each other. The cord connecting the poles is doubled as well, so each circuit has its own conductor going from one pole to the other. |
The LVD-415 has visual voltage indicators (neons) which lit when the voltage between the poles is superior or equal to 110V, 220V, 280V and 415Vac. Length : 1000mm, Weight : Approx. 670g. |
Some Applications for the Double Check are : |
Measure and confirm overhead voltage between lines in all safety due to the clearance from the probes contacts. This is done, for example, using a backet on a truck, then from the bucket, you can reach all the phases and check voltage between each phases. |
Check voltage presence between two conductors or between phase and earth. Measure and detect voltage between bus bars and between bus bar earth. Use where you are not comfortable with your normal test leads. Tips can be changed for different types. |
Available tips : Fork type, Piercing through Insulation, Cone, Flat tip, Others on demand. |
SIÊU THỊ THIẾT BỊ ĐO QUANG MINH - CÔNG TY TNHH ĐẦU TƯ VÀ TT QUANG MINH
ĐT: 04.3873.0880 - Hotline: 090.400.3848 - Fax: 04.3873.0880
Email: kd@sieuthithietbido.com - Website: www.sieuthithietbido.com - www.sieuthithietbidienmay.net